Infoline
Categories
Newsletter

Olympus AU5400

Alternative Biomedical Solutions sells a complete line of Quality Refurbished Olympus Chemistry Immuno Systems.

More details



When you purchase from ABS you get:

- Quality Refurbished Systems at Significant 

   Savings

- Installation and onsite Operator Training

- Warranty – 12 months parts, labor & travel

- Technical Support

- Onsite Response – 24 to 48 hour

- Options – 24/7 and Business Hours

Analytical system

Fully automated for routine, emergency test, urine and homogeneous immunoassays.

Analytical methods

Clinical chemistry and immunological parameters. End point, kinetic assays, fixed time kinetics, and ISE option.

Simultaneously processed analytes

Up to 96 photometric tests and 3 ISE.

Throughput

AU5420: Up to 3200 photometric tests/hour; ISE up to 600 samples/hour. AU5430: Up to 4800 photometric tests/hour; ISE up to 600 samples/hour.

Sample feeder

Racks with 10 samples each (bar-codes on primary tubes and on racks); capability of 300 samples; continuous loading.

Sample tubes

In primary and secondary tubes diameter from 11.5 to 16 mm, height from 55 to 102 mm.

Sample volume

1.6 to 25 µl in 0.1 µl steps (1 µl for repeats).

Reagent supply

Refrigerated (4 °C - 12 °C); 48 positions for R1; 48 positions for R2/module.

Reagent volume

1. Reagent 15-250 µl; 2. Reagent 15-250 µl.

Total reaction volume

120-430 µl.

Reaction cuvette

Quartz cuvettes.

Reaction time

Up to 8 minutes, 22 seconds.

Reaction temperature

37 °C.

Mixing method

With rotating paddles after dispensing sample and reagent.

Photometry system

Direct assay through the reaction cuvette (0-2.5 OD); mono-, bichromatic. measurements possible

Wavelength

13 different wavelengths between 340 and 800 nm.

Cuvette cleaning

Comprehensive cleaning with detergents.

Calibration

Linear and non-linear (linear interpolation), refrigerated calibrator positions.

Data processing

Calculated parameters, blank value correction and correlation. Definition of normal value range, measuring range, pathological values and repeats. Quality controls, printout of abnormal values, pending sample work list and repeat run sample list.

Test requisition

Individual and profile test requisition via on-line, mouse, function keys or optional touch screen.

Safety

Clot detection and crash prevention for sample and reagent dispenser.

On-line

Full uni- and bi-directional communication possible.

Software

Windows NT®; modem capability.

Dimensions (W x H x D) mm

AU5420 ANL: 3960 x 1260 x 1140 DPR: 700 x 1430 x 700mm AU5430 ANL: 5090 x 1260 x 1140 DPR: 700 x 1430 x 700mm